S
ERVER 6015X-3/6015X-T/6015X-8 User's Manual
4-2 General
Safety
Precautions
Follow these rules to ensure general safety:
Keep the area around the 6015X-3/6015X-T/6015X-8 clean and free of
clutter.
The 6015X-3/6015X-T/6015X-8 weighs approximately 38.5 lbs (17.5 kg) when
fully loaded. When lifting the system, two people at either end should lift
slowly with their feet spread out to distribute the weight. Always keep your
back straight and lift with your legs.
Place the chassis top cover and any system components that have been
removed away from the system or on a table so that they won't accidentally
be stepped on.
While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits
or be pulled into a cooling fan.
Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into
contact with printed circuit boards or areas where power is present.
After accessing the inside of the system, close the system back up and secure
it to the rack unit with the retention screws after ensuring that all connections
have been made.
!
Serverboard Battery:
CAUTION
- There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarities (see Figure
4-1). This battery must be replaced only with the same or an equivalent type
recommended by the manufacturer. Dispose of used batteries according to
the manufacturer's instructions.
DVD-ROM Laser:
CAUTION
- this server may have come equipped with
a DVD-ROM drive. To prevent direct exposure to the laser beam and
hazardous radiation exposure, do not open the enclosure or use the unit in
any unconventional way.
Summary of Contents for SUPERSERVER 6015X-3
Page 1: ...SUPERSERVER 6015X 3 SUPERSERVER 6015X T SUPERSERVER 6015X 8 USER S MANUAL 1 0a SUPER...
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System...
Page 100: ...A 6 SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual Notes...
Page 106: ...B 6 SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual Notes...
Page 140: ...C 34 SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual Notes...
Page 144: ...D 4 SUPERSERVER 6015X T 6015X 8 User s Manual Notes...