![SUPERLOLUX HD9 NVR User Manual Download Page 179](http://html1.mh-extra.com/html/superlolux/hd9-nvr/hd9-nvr_user-manual_1403312179.webp)
NVR Software - General notes
177
7.3
Firewalls and SeeTec 5
To ensure that the SeeTec 5 software can function properly even in a network
environment with a firewall, multiple ports must be available on the server
computer by default. The port range is 60000 – 60008 (TCP communication) and
60007 (UDP, image transfer).
The client must also be available on the ports 60000 – 60008, 63000 (TCP) and
60007 (UDP).
Furthermore, the TCP alarm ports of the camera managed on the server computer
must be available to ensure alarm handling.
If encrypted communication between SeeTec server and client is configured, you
have to open the ports 60011 and 60012, as well on both the server and client.
Some cameras use the
RTSP over RTP over UDP
standard for MPEG-4 image
transfer. In this case, the SeeTec server communicates with the camera via TCP
port 554 to determine what is transferred (images / audio, etc). The server also
determines a UDP port for the transfer.
This is why the UDP protocol between the camera and the SeeTec server should not
be blocked under any circumstances.
7.4
User's Guides
You can find all user's guides under
<installation directory>\SeeTec\Manual
.