![Superior SDV35-2 Installation Instructions Manual Download Page 11](http://html1.mh-extra.com/html/superior/sdv35-2/sdv35-2_installation-instructions-manual_1402833011.webp)
11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
SUPERIOR
®
• DIRECT-VENT GAS FIREPLACES (SDV35-N-2) • INSTALLATION INSTRUCTIONS
A
B
D
7
(178)
5-1/8
12-1/8
(308)
10-1/2
(
267
)
C
VENT FRAMING:
TOP VENT WITH ONE
90
°
ELBOW
VENT FRAMING:
REAR VENT WITH
NO ELBOWS
Framing should be
constructed of 2x4
or larger lumber.
Inches (mm)
E
(130)
(130)
7
(308)
(178)
1/2
A
5-1/8
12-1/8
Dimension “E” is the required framing depth when the
finish material (drywall) thickness is 1/2 in. (13mm).
.
o
N
l
e
d
o
M
A
B
C
D
E
SDV35-N-2
in.
mm
42 1/4
1073
37 1/2
953
23 3/4
603
42 1/4
1073
16
406
9
(229)
24-7/8
(632)
40 (1016)
32-1/8
(816)
24-7/32
(615)
16
(406)
(13)
1-5/8
(42)
9
(229)
5-9/16
3/16
(141)
Top View
CONCENTRIC FLUE
FLUE - 4 -1/2 (114)
COMBUSTION AIR - 7-1/2 (190)
FRAMING
SPACERS
(Top and Sides
and Rear)
GAS INLET
(Either Side
and bottom)
Front View
2
-1/2
(63)
ELECTRICAL
INLET
2-3/4 x 2 (70 x 51)
Right Side View
(14)
43 (1092)
12-7/16
9/16
(316)
Inches (Millimeters)
(5)
29-1/2
(749)
19
(406)
35-1/8 (892)
37-5/32
(944)
Overall
unit
height
Note - J-box can be relocated in either the right front
or left front corners of the appliance by relocating the
moveable J-box plate.
5-3/8 (137)
Bottom Gas Inlets
8
-1/2
(216)
6
-3/4
1/2
(171)
3-3/8
(86)
Vertical Venting through the Ceiling
Frame ceiling opening:
Use a
plumb line from the ceiling above
the appliance to locate center of
the vertical run. Cut and/or frame
an opening, 10 1/2 in. x 10 1/2 in.
(267 mm x 267 mm) inside
dimensions, about this center mark
(see Figure 20)
.
Notes
Diagrams, illustrations and photographs are not to scale. Consult installation
instructions. Product designs, materials, dimensions, specifications, colors,
and prices are subject to change or discontinuance without notice.
Thermal Efficiency (%)
Fireplace
Model
Natural Gas
Propane
AFUE EnerGuide
(P4)
AFUE EnerGuide
(P4)
SDV35-N-2
62
53
60
55
Based on CSA P.4.1-09
Figure 12: Fireplace and Framing Specifications
Framing