7.8 Wiper
After entering setup mode, select “Wiper” and press to configure wiper settings: activation
mode and time interval. Select Auto to set automatic wiper cleaning according to the sensor
connected. Select manual to configure automatic cleaning interval.
TC-100:
Auto – Electrode default is 30 minute interval.
Manual – Configure from 2 to 29 minutes.
TC-500, TC-3000, TCS-1000: Auto – Electrode default is 10 minute interval
Manual – Configure from 2 to 9 minutes.
Enter “Electrode Zero” Setup
Press to confirm it.
Press or to
select Wiper mode.
Press to confirm it.
Press or to
adjust wiper cleaning
interval.
Press to confirm it.