56
Function No. : 122
Function Name : Setting the opening of the thread release device for jump section
This opens the pneumatic thread release device when no trimming occurs for the jump section.
Not used (default value)
[Contents] Same as normal use when this function is not selected.
122. Jump Tention
1) DISABLE
Setting
Value
Used
[Contents] When this function is selected, the entry to the program mode is blocked.
2) ENABLE
Function No. : 123
Function Name : Setting a lock to the program mode
This locks the program mode, preventing inexperienced users from modifying designs.
The function is disabled (default).
[Contents] Same as normal use when this function is not selected.
In use
[Contents] The entry to the program mode is prevented when this function is selected.
123. Program Lock
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 124
Function Name : Setting the default position of the clamp
This sets the default position of the clamp. A user can switch the pneumatic lines of the clamp.
The function is disabled (default).
[Contents] Same as normal use when this function is not selected.
As default, the clamp is at the upper position.
<When power is off, the clamp ascends. >
In use
[Contents] Before the setting, switch and connect pneumatic lines A and B.
When switching is completed, set the parameters.
As default, the clamp is at the lower position.
<When power is off, the clamp descends. >
124. Clmp Ref Pos
1) REF UP
2) REF DOWN
Setting
Value
Summary of Contents for SPS/E-5050 Series