34
Function No. : 067
Function Name : Number of stitches to decelerate before ending work
Function No. : 068
Function Name : Decelerating speed before ending work
It is to set the stitch number of when to decelerate before ending the work.
It is to set the number of stitches when the machine should decelerate.
(Factory installed condition : 4)
[Contents] It is to set the number of stitches when the machine should start decelerating
before ending the operation.
067. Decel Stitch
2~16 Stitch
Setting
Value
It is to set the speed the machine should decelerate before ending the work.
It is to set the speed to decelerate before ending the work.
(Factory installed condition : “200”)
[Contents] The speed must be decelerated before ending the work.
The decelerating speed is set here.
068. Decel SPM Trim
200~400spm
Setting
Value
Function No. : 066
Function Name : Set the clamp when the chain is used.
When the chain function is used, the clamp up/down can be set.
The clamp down setting is unused (default).
The clamp down setting is used.
[Contents] In case where three patterns are used consecutively, when the first pattern
work is finished, the second pattern is automatically called, and the clamp
ascends. Therefore, after the pattern work, the clamp ascends.
[Contents] In case where three patterns are used consecutively, when the first pattern
work is finished, the second pattern is automatically called, and the clamp
descends. When the second pattern work is finished, the third pattern is
automatically called, and the clamp descends. After the last third pattern work
is finished and the machine returns to the first pattern, the clamp ascends.
066. Chain Clamp
1)DISABLE
2)ENABLE
Setting
Value