11
Function No. : 014
5
th
Needle Speed Setting
Function No. : 015
6
th
Needle Speed Setting
Function No. : 016
7
th
Needle Speed Setting
User sets the speed for the 7
th
needle.
User sets the speed for the 7
th
needle (default value: 12[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “7) User Define."
016. User_Slow_7
2~25[100ms]
Setting
Value
User sets the speed for the 6
th
needle.
User sets the speed for the 6
th
needle (default value: 10[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “7) User Define."
015. User_Slow_6
2~25[100ms]
Setting
Value
User sets the speed for the 5
th
needle.
User sets the speed for the 5
th
needle (default value: 8[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “7) User Define."
014. User_Slow_5
2~25[100ms]
Setting
Value
Function No. : 017
8
th
Needle Speed Setting
User sets the speed for the 8
th
needle.
User sets the speed for the 8
th
needle (default value: 14[100ms])
[ Contents ] This function is used when the set value of Parameter “009. Slow Start
Main Shaft Acceleration" is “7) User Define."
017. User_Slow_8
2~25[100ms]
Setting
Value
Summary of Contents for SPS/E-5050 Series