Table 1 - Parameter Numbers for Observing and Changing Parameters.
* If Manual Lockout is enabled, the timer cannot operate as a stand-alone timer. In the event of a timer failure, this
parameter cannot be enabled at the timer.
Setting the Address
1) Press and hold the
START/STOP
and
UP
buttons until a .1 appears on the
display (see illustration
A
). This should take about 5-6 seconds. Release the
buttons.
2) Press and release the
START/STOP
button. A period, number (i.e. .3) or
number, period number (i.e. 5.2 ) will be illuminated with the number flashing.
Pressing and holding the
UP
button will cause the display to count up.
Once the count reaches 100, the center period will flash rapidly. This is an
indication that you are over 99. For example, if the display shows a 0.2
with the period flashing, this is address 102. The highest the display will
count up is 254.
4) Press the
UP
or
DOWN
button until the desired address is displayed.
Note:
Set each timer to a unique address. Do not set any address to 0
(unless you are using this timer as a master). Do not set any address over
100. If the period is flashing, you are over address 100.
5)
Press the
START/STOP
button. A .1 will be displayed, with the 1 not
flashing.
To exit Parameter Mode, press and hold the
UP
and
DOWN
buttons together
until the period goes away.
Parm #
Description
Max #
Default
Notes
1
Address
255
254
Station address of timer (each tanning system must have a unique address)
2
Beep Mode
1
0
Used for High Power beds. 0=Alarm only, 1=Alarm and Flip
3
Session Delay Time
5
0
Session delay after which time the tanning system will turn on automatically
4
Current Sense
1
0
For the Sentry™ Option. 0=Disabled, 1=Enabled.
5
Session Counts
65535
0
Total session counts (number of times the tanning systems has been turned on/off)
6
Lamp Hours
65535
0
Lamp hours for each bed.
7
Bed Hours
65535
0
Number of hours the tanning system has been operating.
8
Manual Session Counts
65535
0
Counts the number of sessions the timer has ran.
9
Clean Room
1
1
0 = Clean Room Disabled, 1 = Enabled
10*
Manual Lockout
1
0
0 = Stand Alone Enabled, 1 = Disabled
13
Cool Down Mode
10
0
0 = Disabled, 1-10=Enabled. Time delay in minutes allowing bed to cool.
15
Fixed Session Counts
65535
0
Counts number of sessions ran through the T-Max® 3A. This value cannot be
changed at all. Used as point of reference.
17
Clean Clear
1
0
0 = Press and hold the Up button for 3-4 seconds to clear the clean room. 1 = Press
and release the Up button to clear instantly
18
Redisplay
2
0
0 = After a session ends and the clean room is cleared, the timer will show a 0. 1 =
After session ends and the clean room is cleared, the timer will show the last
session time entered. 2-10 = After the session ends and the clean room is cleared,
the max. time will show on the timer.
19
TPI Feature
1
0
0 = Configured to operate via Intellitan
®
or T-Max
®
controller. 1 = Configured to
operate via a Third Part Controller (will accept contact closure)
20
External Speaker
1
0
0 = Speaker on timer, 1 = External Speaker will be used.
21
Auto bed shutoff
1
0
0 = tanning system will stay on when intercom is active. 1 = tanning system will shut
off and go to pause mode if intercom is active.
22
Pause time
1
0
0 = When tanning system is paused, session time will continue to count down. 1 =
When tanning system is paused, session time will not count down.