118
SPARC T3-2 Server Service Manual • December 2013
■
If the memory riser Service Action Required LED is off, all DIMMs on this riser
are operating properly.
■
If the memory riser Service Action Required LED is on (amber), one or more of
the DIMMs installed on this riser is faulty or misconfigured.
3. Remove the memory riser containing the faulty DIMM. Place the memory riser
on an ESD-protected work surface.
See
“Remove a Memory Riser” on page 120
.
4. Press the Remind button on the memory riser to identify the faulty DIMM. An
amber Fault LED will light next to the faulty DIMM.