96
SPARC T3-2 Server Service Manual • December 2013
Note –
The front and rear panel Service Action Required LEDs are also lit when the
system detects a fan module fault. The system Overtemp LED might also light if a
fan fault causes an increase in system operating temperature.
Related Information
■
“Front Components” on page 1
■
“Rear Components” on page 3
■
“Extend the Server to the Maintenance Position” on page 72
■
“Remove a Fan Module” on page 96
▼
Remove a Fan Module
Caution –
If you remove one of the fans in the back row (fans 3, 4, or 5), replace it
within 30 seconds to prevent overheating of the server.
Caution –
The fan module contains hazardous moving parts. Unless the power to
the server is completely shut down, replacing the fan modules is the only service
permitted in the fan compartment.
This procedure can be performed by customers while the server is running. See
“Hot
Service, Replaceable by Customer” on page 66
for more information about hot
service procedures.
1. Prepare for servicing:
a. Attach an antistatic wrist strap.
b. Extend the server to the maintenance position.
Service Required
Amber
The fan module is
faulty.
LED
Color
Status When Lit
Summary of Contents for SPARC T3-2
Page 1: ...SPARC T3 2 Server Service Manual Part No E20793 05 December 2013 ...
Page 10: ...x SPARC T3 2 Server Service Manual December 2013 ...
Page 26: ...14 SPARC T3 2 Server Service Manual December 2013 ...
Page 72: ...60 SPARC T3 2 Server Service Manual December 2013 ...
Page 112: ...100 SPARC T3 2 Server Service Manual December 2013 ...
Page 120: ...108 SPARC T3 2 Server Service Manual December 2013 ...
Page 150: ...138 SPARC T3 2 Server Service Manual December 2013 ...
Page 174: ...162 SPARC T3 2 Server Service Manual December 2013 ...
Page 186: ...174 SPARC T3 2 Server Service Manual December 2013 ...
Page 194: ...182 SPARC T3 2 Server Service Manual December 2013 ...
Page 200: ...188 SPARC T3 2 Server Service Manual December 2013 ...
Page 206: ...194 SPARC T3 2 Server Service Manual December 2013 ...
Page 212: ...200 SPARC T3 2 Server Service Manual December 2013 ...
Page 216: ...204 SPARC T3 2 Server Service Manual December 2013 ...
Page 222: ...210 SPARC T3 2 Server Service Manual December 2013 ...