Chapter 5
Removing and Replacing Miscellaneous Internal Components
101
14. Connect the front fan assembly cables to the system board connectors.
See
to locate the system board connectors.
Note –
Refer to the chassis label for an illustration of the correct routing of the
cables.
15. Connect the interface board SCSI and IDE cables to the system board.
See
16. Press the SCSI/IDE cable clamp back down to secure the SCSI interface and IDE
cables.
The cable clamp is attached to the chassis and has a green cap. See
for
the location of this clamp.
17. Connect the PDB wiring harness to the system board.
See
18. Place the PCI riser card assembly in position in the server (
a. Press down on the top of the assembly to fully seat it into the system board.
b. Tighten the two captive screws that secure the PCI riser card assembly to the
system board (
).
19. Insert all PCI cards back into the PCI riser card assembly.
See
“Installing a PCI Card” on page
.
20. Install the air duct and rear fan assembly.
See
“Installing or Closing the Air Duct and Rear Fan Assembly” on page
21. Close the rotating service module.
See
“Closing the Rotating Service Module” on page
.
22. Install the server cover.
See
“Installing the Server Cover” on page
23. Power on the server.
See
Summary of Contents for Netra 240
Page 7: ...Contents vii Index 133...
Page 8: ...viii Netra 240 Server Service Manual June 2004...
Page 12: ...xii Netra 240 Server Service Manual June 2004...
Page 70: ...52 Netra 240 Server Service Manual June 2004...
Page 84: ...66 Netra 240 Server Service Manual June 2004...
Page 120: ...102 Netra 240 Server Service Manual June 2004...
Page 124: ...106 Netra 240 Server Service Manual June 2004...
Page 132: ...114 Netra 240 Server Service Manual June 2004...