Clearing Disk Faults
When the Solaris FMA facility detects faults, the faults are logged and displayed on
the console. After the fault condition is corrected, for example by replacing a faulty
disk, you must clear the fault.
fmadm
Command
The
fmadm
command can be used to view and modify system configuration
parameters that are maintained by the Solaris Fault Manager. The
fmadm
fault
command is primarily used to determine the status of a component involved in a
fault. The
fmadm
command can be used to:
■
View the set of diagnosis engines and agents that are currently participating in
fault management.
■
View the list of system components that have been diagnosed as faulty.
■
Perform administrative tasks.
In cases, where the disk fault is cleared, some persistent fault information can
remain and result in erroneous fault messages at boot time. To ensure that these
messages are not displayed, the
fmadm repair
UUID
command should be
performed.
Using the fmadm Command to Clear Faults
●
Clear faults by typing the
fmadm repair
command. For example:
For more information, see the
fmadm
(1M) man page.
#
fmadm repair 9a2c5052-687b-e196-b12b-8035267c3031
Summary of Contents for Fire X4540
Page 14: ......
Page 21: ...Chapter 1 Introduction to the Sun Fire X4500 Server 7 FIGURE 1 4 Disk Drive Locations ...
Page 40: ...26 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 62: ...48 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 72: ...58 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 78: ......
Page 120: ...106 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 128: ...114 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 138: ...124 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...