Chapter 12
Sun Fire X4540 Fault Management Architecture
111
Diagnosing Disk Faults
To determine which disk failed, you can view the FMA fault error log, use
fmdump
command, or open the system cover to look for illuminated LEDs. If you use the
fmdump
command to isolate a disk, you should also open the system cover and look
for amber LEDs. The following is an example of the
fmdump
command you can use
to display disk faults.
The following is an example of information that is displayed when a disk fault is
detected and the
fmdump
command is used.
Based on the information displayed, you can determine which disk failed and the
attachment point.
For more information, see the
fmdump
(1M) man page.
#
fmdump -v -u uuid
CODE EXAMPLE 12-2
fmdump
Command Diagnose Disk Fault
TIME
UUID
SUNW-MSG-ID
May 09 13:38:24.9404 9a2c5052-687b-e196-b12b-8035267c3031 DISK-
8000-0X
100% fault.io.disk.predictive-failure
Problem in: hc:///:serial=VDK41BT4C7PJYS:part=HITACHI-
HDS7225SBSUN250G-527N7PJYS:revision=V44OA81A/motherboard=
0/hostbridge=2/pcibus=9/pcidev=8/pcifn=0/pcibus=11/pcidev=
1/pcifn=0/sata-port=6/disk=0
Affects: hc:///component=
sata5/6
FRU: hc:///component=HD_ID_29
Summary of Contents for Fire X4540
Page 14: ......
Page 21: ...Chapter 1 Introduction to the Sun Fire X4500 Server 7 FIGURE 1 4 Disk Drive Locations ...
Page 40: ...26 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 62: ...48 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 72: ...58 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 78: ......
Page 120: ...106 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 128: ...114 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...
Page 138: ...124 Sun Fire X4500 X4540 Servers Administration Guide October 2008 ...