6-3
6. Functions
|
Operation Settings
6. Functions
Editable items
Details
View Edit View Edit
Arc Pause
Stops the splicing process temporarily before
arcing. If you would like to check fiber offset
and fiber end faces during the process, set
this function to ON.
✔
✔
✔
✔
Auto Start
Automatically starts the splicing process
when the fiber is inserted in the splicer and
the hood is closed.
✔
✔
✔
✔
Heater Auto Start
Automatically starts the heating process
when the fiber is placed into the heat shrink
oven.
✔
✔
✔
✔
Additional Arc
Additional arc is available by setting this
function to ON. If an arc is insufficient, an
additional arc should be performed.
✔
✔
✔
✔
Additional Arc Settings
Allows to adjust the arc power for additional
arc.
✔
✔
✔
✔
Fiber Insertion Screen
Single (X or Y) screen type or dual (X above
Y, X beside Y) screen type can be selected
in each step of the splicing process.
→
For
more information, refer to the next page.
- -
✔
✔
Pre-Fusion Screen
-
-
✔
✔
Arc Screen
- -
✔
✔
Post-Fusion Screen
-
-
✔
✔
Est. Loss Screen
-
-
✔
✔
Summary Data(Offset)
You can select the type of splice data that
displayed on the information screen after
splice
.
- -
✔
✔
Summary Data(Angle)
- -
✔
✔
Summary Data(Gap)
- -
✔
✔
Summary Data(Irregular)
- -
✔
✔
Post splice Action
(Proof-Reset)
Allows to select an action to be done after
splicing, i.e. a proof test is carried out or
not, and reset action is automatically per-
formed or not.
- -
✔
✔
Condition Auto Change
If it's set to ON, when the count of a loaded
fiber does not match the fiber count of a se-
lected splice program, the splicer automati-
cally changes to a correct splice program,
proceeding to splicing.
- -
✔
✔
Clamp
This function sets the Auto Clamping Ad-
justment System to ON or OFF
- -
✔
✔
Active
-
ACAS
The Active-ACAS function is set to ON by
default. If the offset exceeds a threshold
(Default: 5 um), the clamps and Z stages
automatically move to adjust the offset be-
low the threshold.
✔
✔
✔
✔
A pass code is required to log in to
Administrator mode.
▸
P.8-1.
■
Operation Settings details