OPERATING MANUAL FOR SELECT EDI 60
L300180 Iss:A
27
•
To obtain access to the filter screen unscrew the black knurled top anti-
clockwise. The screen will then be exposed. Pull the screen away
from the housing and clean away any debris.
•
Once cleaned, replace the screen and black top.
•
Replace the rear, side, top and front cover using the reverse procedure
and switch on the water supply. Start the unit from the power on
screen
7.3
Replace main PCB battery
(Ref to Section 9 for re-order part no. of replacement battery)
Note: Replacement of the battery should only be carried out by trained
and/or SUEZ approved technicians.
1. Ensure unit is in “Power On” mode.
2. Turn the unit off by using the rear isolation rocker switch, ensure switch
is in the “O” position and then isolate the unit from the electrical mains
supply by removing the power cord from the wall socket or from the
connection on the rear of the unit.
3. Turn off the incoming water supply to the unit.
4. The battery is located within the main PCB which is accessed via
removal of the top cover.
5. Pull the Pod forward to disengage from the top cover. The top cover can
then be lifted away from the unit. Once removed the battery can be clearly
seen on the main PCB, prise the battery out of its holder. (Refer to
“location Lithium battery on main PCB diagram”)
7. Refit the new battery ensuring the,
(+)
positive side is facing upwards,
the battery should be pressed gently until the four clamps in the retainer
“snap” over the battery fully. Refer to Section 11.4.5 to check details of
battery before fitting.
8. Dispose of the old battery according to guidelines in Section 13.5.
9. Refit the top cover and push the Pod back ensuring it engages with the
cover.
10. Reinstate the mains power supply and check the operation of unit.
11. You may be requested to reset the Time & Date, refer to Section 6.4.1
Warning:
Incorrect fitting of the battery could cause irreversible damage to the main PCB. Ensure
the
(+) positive
side of the battery is facing upwards. Always use the recommended
battery, Part No. R083349. The battery has a five year in-service life, but we recommend
that it is replaced every three years. However, if the unit has been switched off and
disconnected from the mains supply for more than 1 year we would recommend that
the battery is replaced.