OPERATING MANUAL FOR SELECT EDI 60
L300180 Iss:A
29
8
DISINFECTION PROCEDURE
Sanitisation of the unit should be carried out at least once every 6 months.
•
Switch the unit off by pressing the STOP button.
•
The unit will now have reverted to the POWER ON screen.
•
Turn off the water supply to the unit.
•
Leave the unit to stand for 60 seconds to relieve the pack water
pressure.
•
Pull away the front door cover to reveal the media cartridge packs.
•
Remove the left hand Pre-Treatment pack and discard.
o
To sanitise the unit insert a cleaning pack adaptor (Suez part
number L998549) into the left hand media pack location.
•
Turn on the water supply and press the menu button.
•
Select ‘Clean Routine’ from the menu and follow the ‘on screen’
instructions.
•
When the clean routine has completed, isolate the water supply and
allow the unit to stand for 60 seconds to depressurise.
•
Remove the cleaning / descale pack and dispose of according to local
regulations.
•
Fit a new ‘Pre-Treatment pack and follow the ‘on screen’ instructions.
The unit will revert to the ‘Power On’ screen and be ready for operation