7.2
Cleaning the inlet screen filter
It is recommended that this filter is cleaned at least once per year. The
inlet screen filter is located in the rear of the unit and can be cleaned as
follows:
•
Switch off the water supply at source
•
To relieve any residual water pressure, momentarily switch the unit on
then off.
•
Remove the right hand side panel of the unit.
o
To do so first remove the front cover by pulling it gently from the
unit using the hand holds provided.
o
Pull the pod assembly gently forward to disengage the top cover
retaining pin.
o
Remove the top cover by lifting up the front and sliding gently
backwards.
o
Remove the four retaining screws holding the side panel in place
and slide gently backwards.
o
Remove the rear panel retaining screws and move the panel
aside.
Screen filter