Form No. 702718 Rev. A March, 2005
61
Owner’s Manual - Regal Intensive Care Unit
Figure 70. Fuse Cap and Fuse
Fuse Cap
Fuse
Figure 69. Floor Temperature Fuses
Floor
Temperature
Fuses
Replacing Floor
Temperature Fuses
Two fuses are provided for protection of the left and right floor tem-
perature systems (Figure 68). Both fuses are 3AG fast-acting, 250 V,
2 amp. If you need replacement fuses you can order them from SSCI,
however, they are standard items and can be obtained faster and
cheaper at your local hardware or electronics supply store.
Removal
Press in on the fuse cap, then twist about one-quarter turn counter-
clockwise, and pull out the fuse cap and fuse (Figure 70).
Inspection
Inspect the thin, curly metal wire inside the transparent center
section of the fuse (Figure 70). If the wire is intact, the fuse is OK.
If the wire is burned or broken, the fuse is bad and must be re-
placed.
Installation
1.
Place either end of the fuse into the fuse cap.
2.
Engage the “ears” behind the fuse cap into the gaps in the
fuse holder.
3.
Press in on the fuse cap, and turn about one-quarter turn
clockwise until it snaps into place.
Summary of Contents for REGAL INTENSIVE CARE UNIT 12019-01-NGFREP
Page 12: ...x SSCI Suburban Surgical Company Inc Table of Contents Notes...
Page 20: ...8 SSCI Suburban Surgical Company Inc Chapter 1 General Information Notes...
Page 44: ...32 SSCI Suburban Surgical Company Inc Chapter 2 Description of Components Notes...
Page 148: ...136 SSCI Suburban Surgical Company Inc Chapter 5 Repairs Replacements Notes...
Page 168: ...156 SSCI Suburban Surgical Company Inc Chapter 6 Troubleshooting Notes...
Page 170: ...A 2 SSCI Suburban Surgical Company Inc Appendix Thispageleftblankintentionally...
Page 174: ...A 6 SSCI Suburban Surgical Company Inc Appendix Thispageleftblankintentionally...
Page 183: ...Inside back cover This page left blank intentionally...