Form No. 702718 Rev. A March, 2005
29
Owner’s Manual - Regal Intensive Care Unit
43 - Circulating Fans
Three circulating fans (Figures 29 and 33) move air at approxi-
mately 50 CFM (cubic feet per minute) and are designed to handle
the enriched oxygen environment in which they operate. The system
achieves a complete air change in the full-size animal compartment
every 30-seconds, and 15-seconds in the half-size compartment
when the clear acrylic divider is in place. The fans start and stop
automatically as the main on/off switch is turned to On and Off.
Figure 33. Circulating Fans
43 -
Circulating
Fans (3)