Built-In Refrigeration
9
subzero.com/specs
Electrical Requirements
Power Supply
220-240 V AC, 50/60 Hz
Circuit Breaker
10 amp
Receptacle
3-prong grounding-type
Plumbing Requirements
Water Supply Line
6.35 mm OD copper line
Water Pressure
2.1–6.9 bar
Excess Water Line for Connection
914 mm
76 mm
457 mm
FRONT VIEW
FLOOR
152
mm
Location of water supply—
rear.
Location of water supply—
bottom.
TOP VIEW
BACK WALL
13 mm
457 mm
152
mm
FRONT VIEW
1918 mm
FROM
FLOOR
178
mm
E
152
mm
Location of electrical supply.
Planning Information
ELECTRICAL REQUIREMENTS
International models from the factory designed without a
transformer require a 220-240 V AC, 50/60 Hz electrical
supply, fused at the correct rating for the unit. If required
by local or national codes, the power cord can be easily
replaced using the power inlet device.
For all built-in models, the electrical supply should be
located within the shaded area shown in the illustration.
Follow local codes and ordinances when installing the
receptacle. A separate circuit servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
PLUMBING REQUIREMENTS
For built-in models with an automatic ice maker, the water
supply line should be located within the shaded area
shown in the illustrations. The water supply line should be
connected to the house supply with an easily accessible
shut-off valve between the supply and the unit. Do not use
self-piercing valves. A saddle valve kit (4200880) is avail-
able through your authorized Sub-Zero dealer. The water
line must not interfere with installation of the anti-tip
brackets.
IMPORTANT NOTE:
A reverse osmosis system can be
used provided there is constant water pressure of 2.1 bar
to 6.9 bar supplied to the unit at all times.