Wine Storage
57
subzero.com/specs
Planning Information
DUAL INSTALLATIONS
If you are installing a wine storage unit next to an existing
Sub-Zero unit, you may have to allow for a filler strip.
If you are installing a model ICB427G or ICB427RG next to
an existing integrated unit, with 51 mm or less between
the units, an optional heater kit will need to be installed to
prevent moisture from forming between the units. These
optional heater kits are avail able through your authorized
Sub-Zero dealer. For local dealer information, visit the find
a showroom section of our website, subzero.com.
ELECTRICAL REQUIREMENTS
International models from the factory designed without a
transformer require a 220-240 V AC, 50/60 Hz electrical
supply, fused at the correct rating for the unit. If required
by local or national codes, the power cord can be easily
replaced using the power inlet device.
The electrical supply should be located within the shaded
area shown in the illustration for your specific model.
Follow local codes and ordinances when installing the
receptacle. A separate circuit, servicing only this appli-
ance, is required. A ground fault circuit interrupter (GFCI)
is not recommended and may cause interruption of opera-
tion.
Electrical Requirements
Power Supply
220-240 V AC, 50/60 Hz
Circuit Breaker
10 amp
Receptacle
3-prong grounding-type
FRONT VIEW
394 mm
76 mm
51 mm
E
Model ICB424G.
Models ICB427G and
ICB427RG.
330 mm
6
mm
114
mm
POSITION OUTLET WITH
GROUNDING PRONG
TO THE RIGHT
FLOOR
64 mm
FRONT VIEW
E
FRONT VIEW
1918 mm
FROM
FLOOR
178
mm
E
152
mm
Model ICBWS-30.