Troubleshooting Guides
Integrated
(700-
3
BASE)
Series
8-15
#3758424 - Revision B - December, 2005
PROBLEM
POSSIBLE CAUSE
TEST / ACTION
S. Lights Stay ON when
Drawers Closed - (May be
Accompanied by /Drawer
Ajar Alarm Bell)
T. Drawers Not Able to Close
Completely
U. Drawers Uneven
Door or Drawer Ajar
a. Food product obstruction
b. Drawer closer tripped backwards
Faulty Light Switch
Food Product Obstruction
Drawer Closer Tripped Backwards
Improper Drawer Panel Installation
Unit Not Level
a. Move obstruction.
b. Trip drawer closer forward
Check operation of light switches, lights off
when switch is depressed. Replace switch
if defective.
(
NOTE:
Two light switches in
unit)
Move obstruction.
Trip drawer closer forward
The drawers are non-adjustable. Instead,
the drawer panels must be adjusted if there
is an alignment problem. Refer to the
Installation Manual and/or installation video
for panel installation and adjustment.
Check levelness of unit. If un-level, turn
front leveling legs counterclockwise to raise
front or clockwise to lower it. Rear levelers
are adjusted from front of base by turning
adjusting screw clockwise to raise rear or
counterclockwise to lower it. Refer to the
Installation Manual and/or installation video
for complete installation and leveling instruc-
tions.
Summary of Contents for 700-3 BASE
Page 2: ......
Page 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Page 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Page 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Page 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Page 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Page 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...