Component Access/Removal
Integrated
(700-
3
BASE)
Series
7-2
#3758424 - Revision B - December, 2005
COMPONENT ACCESS AND REMOVAL
This section explains how to adjust, access and/or remove 700-3 Series base unit components. If different models
have similar procedures, they are grouped together under the appropriate heading. The units covered in the proce-
dures are listed between brackets after the heading.
This section is arranged as follows:
..............................................................................................................
Page:
• Exterior Cosmetic / Mechanical Components ........................................................................................................................
7-3
• Interior Cosmetic / Mechanical Components ........................................................................................................................
7-5
• Compressor Area Mechanical Components ........................................................................................................................
7-15
• Sealed System Components..................................................................................................................................................
7-20
An attempt has been made to arrange these procedures in such a way as to simulate which components would
need to be removed first in order to gain access to other components. When following a component removal proce-
dure, it may be necessary to reference another component removal procedure listed earlier in this section.
NOTE:
Before continuing, please take note of the WARNINGS and CAUTIONS below.
•
IF IT IS NECESSARY TO REMOVE A UNIT FROM ITS INSTALLATION, REMEMBER THAT THE UNIT
COULD TIP FORWARD WHEN PULLED FORWARD BEYOND THE ANTI-TIP COMPONENTS, RESULTING
IN SERIOUS INJURY OR DEATH. PULLING A UNIT FROM ITS INSTALLATION SHOULD ONLY BE PER-
FORMED BY AN AUTHORIZED SERVICE TECHNICIAN OR INSTALLER.
•
TO AVOID ELECTRIC SHOCK, POWER TO THE UNIT MUST BE DISCONNECTED WHENEVER ACCESS-
ING AND/OR REMOVING COMPONENTS POWERED BY ELECTRICITY OR COMPONENTS NEAR OTHER
ELECTRICAL COMPONENTS. IF THE UNIT IS PLUGGED IN, BUT HAS NOT BEEN SWITCHED ON BY
PRESSING THE UNIT ON/OFF KEY, 115 VOLTS AC IS STILL PRESENT AT THE MAIN CONTROL BOARD.
•
IF REMOVING A DRAWER REMEMBER THAT DRAWERS ARE HEAVY. IF THEY WERE TO FALL, THEY
COULD CAUSE SERIOUS PERSONAL INJURY.
•
If working in the compressor area, remember that compressor and tubing may be hot.
•
If working on or around the evaporator or condenser, remember that evaporator and condenser fins are
sharp.
Summary of Contents for 700-3 BASE
Page 2: ......
Page 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Page 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Page 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Page 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Page 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Page 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...