Electronic Control System
Integrated
(700-
3
BASE)
Series
3-19
#3758424 - Revision B - December, 2005
BR-3 Thermistor Code Table
THERMISTOR LOCATION
CODE
Refrigerator Compartment
r
Evaporator
E
ELECTRONIC CONTROL TROUBLESHOOTING INPUT OPERATIONS
The following few pages explain troubleshooting input operations performed at the control panel. The input opera-
tions described are Diagnostic Mode, Manual Component Activation Mode and Temperature Log Recall.
Diagnostic Mode
Initiating Diagnostic Mode allows the Service Technician to observe real-time temperature readings from all thermis-
tors without temperature averaging.
To initiate Diagnostic Mode, the unit must be ON, then press and hold either COLDER key, and press the UNIT
ON/OFF key, then release both keys (See Figure 3-33). The left display area will show the real-time temperature of
the thermistor, the right display area will show the thermistor location code, and all LCD indicators will illuminate.
Pressing either COLDER key while in Diagnostic Mode will toggle forward to the next thermistor location (See
Figures 3-34 & 3-35), while pressing either WARMER key while in Diagnostic Mode will toggle backward to the pre-
vious thermistor location.
NOTE:
If the COLDER and UNIT ON/OFF keys are pressed and held for 10 seconds, Manual Component
Activation Mode will be initiated (this is covered later in the section).
NOTE:
Diagnostic Mode will end 20 seconds after the last key stroke.
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
OFF
SERVICE
ICE
Figure 3-33. Initiate Diagnostic Mode - Press and Hold Either COLDER Key, Then UNIT ON/OFF Key
(“F” Indicates Freezer Compartment)
Figure 3-34. Toggle Through Temperature Readings - Press Either COLDER Key
(“r” Indicates Refrigerator Compartment)
Figure 3-35. Toggle Through Temperature Readings - Press Either COLDER Key
(“E” Indicates Evaporator)
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
OFF
SERVICE
ICE
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
OFF
SERVICE
ICE
BCI-3 Thermistor Code Table
THERMISTOR LOCATION
CODE
Freezer Compartment
F
Refrigerator Compartment
r
Evaporator
E
BFI-3 Thermistor Code Table
THERMISTOR LOCATION
CODE
Freezer Compartment
F
Evaporator
E
Summary of Contents for 700-3 BASE
Page 2: ......
Page 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Page 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Page 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Page 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Page 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Page 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...