Monitor Icemaker System and Display If Service is Needed
The microprocessor observes the power supplied to the icemaker water valve solenoid. If the solenoid is energized
for more than 15 seconds, power to the icemaker system is disabled for 24 hours and an error code is logged (EC
30). (See Figure 3-24) If this happens five consecutive times, ICE and SERVICE on the LCD will flash and the ICE
ON/OFF key will be disabled (See Figure 3-25).
NOTE:
To clear the ICE and SERVICE error indicators, and reactivate the ICE ON/OFF key, the problem must be
corrected, then the unit must be switched OFF and back ON, and the Alarm key must be pressed for 15 seconds to
clear the Error Code.
NOTE:
To allow ice to freeze fully and reduce effects of low water pressure, power to the icemaker system is inter-
rupted for 45 minutes after each ice harvest. This can be bypassed for service purposes by switching the icemaker
system OFF, then back ON by pressing the ICE ON/OFF key.
NOTE:
When in Sabbath Mode, icemaker system is disabled. Sabbath Mode will be covered later.
Figure 3-25. ICE & SERVICE Flashing if solenoid energized 15 seconds, every 24 hours, 5 consecutive times
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
SERVICE
ICE
Figure 3-24. 700BCI-3 Signal Trace Schematic - Icemaker Operation and Solenoid Monitoring
THERMAL
PINK
SWITCH
ICEMAKER
FUSE
60 CYCLES
BLACK
L1
NEUTRAL
WHITE
(OPTIONAL)
ICEMAKER
TAN
ICEMAKER
VALVE
WHITE
HIGH VOLTAGE SCHEMATIC
115 VOLTS
MAIN BOARD
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
WHITE
TAN
TAN
J5
J3
J4
J6
P2
J2
P1
P3
P4
M
M
M
M
1. 115 Volts AC
to solenoid
monitored.
2. If solenoid
energized
more then
15 seconds,
power to IM
system
interrupted
for 24 hours.
Summary of Contents for 700-3 BASE
Page 2: ......
Page 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Page 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Page 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Page 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Page 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Page 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...