Electronic Control System
Integrated
(700-
3
BASE)
Series
3-22
#3758424 - Revision B - December, 2005
Temperature Log Recall Mode
The electronic control system is equipped with a temperature history data storage system. This system logs/stores
the average temperature of each individual thermistor every two hours, along with any event indicators (explained
later in this section), that may have occurred. These two-hour periods are referred to as
“indexes”.
Up to 168
indexes can be stored for each compartment, making it possible to observe the preceding fourteen days of the unit’s
temperature history
(each index equals 2 hour temperature average; 2 hours X 168 indexes = 14 days).
After 168
indexes are stored, each new index will bump the oldest index. Index number “1” being the most recent two-hour
temperature average and index number “168” being the oldest. Accessing this temperature history data so it can be
viewed on the LCD is accomplished by initiating Temperature Log Recall Mode.
There are two ways to initiate Temperature Log Recall Mode. One allows viewing of compartment temperature his-
tory only (see below), the other allows viewing of compartment temperature history and evaporator temperature his-
tory (see following page).
Initiate Temperature Log Recall Mode To View Compartment Temperature History Only
- Begin with the unit
ON. Now, press and hold the desired compartment WARMER key, then press the UNIT ON/OFF key, then release
both keys (See Figure 3-42). The left display area on the LCD will show average compartment thermistor tempera-
ture and in the right display area will be the index number. The first index number will be “1”, indicating the most
recent two-hour temperature average. The right display area will also flash the thermistor location code at 3 second
intervals (See Figure 3-43).
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
Figure 3-42. Initiate Temperature Log Recall Mode To View Compartment Temperature History Only -
Press and Hold Desired WARMER Key, Then Press UNIT ON/OFF Key
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
Figure 3-43. Thermistor Location Code Flashes Every 3 Seconds
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
Figure 3-44. Toggle Up Through Indexes - Press WARMER Key in Consecutive Key Strokes
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
Figure 3-45. Toggle Down Through Indexes - Press COLDER Key in Consecutive Key Strokes
To toggle up through the indexes (from 1 to 168), press the same WARMER key in multiple key strokes (See Figure
3-44). To toggle down through the indexes (from 168 to 1), press the corresponding COLDER key in multiple key
strokes (See Figure 3-45).
Summary of Contents for 700-3 BASE
Page 2: ......
Page 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Page 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Page 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Page 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Page 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Page 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...