Electronic Control System
Integrated
(700-
3
BASE)
Series
3-9
#3758424 - Revision B - December, 2005
Showroom Mode
Showroom Mode was incorporated into the electronic control system so that units could be displayed in a showroom
setting. When in Showroom Mode, all cooling functions are disabled, but the lighting system and LCD remain
active.
To initiate Showroom Mode, the unit must first be switched OFF using the UNIT ON/OFF key (See Figure 3-14).
With the unit switched OFF, press and hold either pair of WARMER and COLDER keys, then press the UNIT
ON/OFF key, then release all three keys (See Figure 3-15).
To return unit to normal operating condition, repeat the steps above.
NOTE:
Always recheck set-points after returning unit to normal operating condition.
NOTE:
It is possible to determine if a unit is in Showroom Mode by initiating Diagnostic Mode. If “Sr” is observed in
the left temperature display area during Diagnostic Mode, the unit is in Showroom mode. Initiating Diagnostic Mode
is covered later in this section.
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
Figure 3-15. After Unit is Switched OFF, Press and Hold the WARMER and COLDER Keys,
Then Press the UNIT ON/OFF Key
Figure 3-14. To Enter (or Exit) Showroom Mode, Switch Unit OFF First
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
OFF
Manual Freezer Evaporator Defrost
Manual Freezer Evaporator Defrost was incorporated into the electronic control to assist in servicing the appliance.
To manually defrost the freezer evaporator, press and hold the ICE ON/OFF key for 5 seconds (See Figure 3-16).
NOTE:
Manual Freezer Evaporator Defrost will not operate if unit is in Sabbath Mode.
Figure 3-16. Initiate Manual Freezer Evaporator Defrost - Press and Hold the ICE key for 5 Seconds
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
ICE
Press and hold for 5 seconds
Summary of Contents for 700-3 BASE
Page 2: ......
Page 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Page 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Page 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Page 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Page 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Page 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...