Page 97
Component Access/Removal
Integrated (
Integrated (
700-
700-
2) Series
2) Series
7-30
#
3756780
- Revision D - July, 2005
Sump Cover Assembly Removal (All Base Units)
The front of the sump cover is held in place with three
screws that pass through the cover and into the floor of
the unit. At the rear of the sump cover, three screws
pass through the cover into a flange at the bottom of
the back duct.
To access the sump cover, remove the bottom drawer
and the bottom drawer closer. On the 700BFI-2, the
icemaker will also need to be removed.
(Removing the
top drawer is not necessary, but will make this task eas-
ier.)
Remove the sump cover by extracting the three screws
at the front of the sump cover and the three screws at
the back.
ward and lift up.
Evaporator Thermistor Removal (All Base Units)
The evaporator thermistor is fastened by cable ties to a
return elbow of the evaporator, on the right side.
To access the evaporator thermistor, remove the bottom
drawer, bottom drawer closer and the sump cover.
(Removing the top drawer is not necessary, but will
make this task easier.)
Then, disconnect the thermistor
electrical leads. Cut the cable ties which hold the ther-
mistor to the evaporator and lift the thermistor out of the
sump area.
NOTE:
You may see a Y-harness between the thermis-
tor electrical connections, with wires exiting through the
heat exchanger hole in the sump. This is for factory
test purposes and it can be removed or bypassed.
Defrost Terminator Removal (700BF/I-2 Only)
The defrost terminator in the 700BF/I-2 is attached to a
return elbow of the evaporator, on the right side.
To access the defrost terminator, remove the bottom
drawer, bottom drawer closer, icemaker and the sump
cover.
(Removing the top drawer is not necessary, but
will make this task easier.)
Then, disconnect the termi-
nator electrical leads. Disengage the terminator clip
from the tubing and lift the terminator out of the sump
area.
NOTE:
When reinstalling the defrost terminator, it must
be attached to the the same elbow it was removed
from. Failure to do so could cause shortened defrost
times which will lead to incomplete defrost.
Figure 7-76. Sump Cover Removal
Remove six screws
Sump Cover
Figure 7-77. Evaporator Thermistor Removal
Figure 7-78. Defrost Terminator Removal, BF/I-2
Evaporator Thermistor
Thermistor Electrical Leads
Defrost Terminator
Terminator Electrical Leads