Page 35
Electronic Control
Integrated (
Integrated (
700-
700-
2) Series
2) Series
3-25
#
3756780
- Revision D - July, 2005
Figure 3-52. Initiate Manual Component Activation Mode -
Press and Hold Desired COLDER Key and UNIT ON/OFF Key for 10 Seconds
Manual Component Activation Mode
After serial #1759493 (700TC/I-2), #1759163 (700TR-2) and #1757258 (700TF/I-2 & 700TF/I-2V), a
Manual
Component Activation Mode was added to the electronic control system. Manual Component Activation Mode
allows a Service Technician to energize a cooling system for five minutes. When activated, the chosen compart-
ment’s compressor and evaporator fan are energized along with the condenser fan. While in Component Activation
Mode, the evaporator temperatures for that compartment are displayed on the LCD. This also allows the Service
Technician to check for proper voltage readings at the activated components without having to wait for the compart-
ment to call for cooling.
To initiate Manual Component Activation Mode, the unit must be ON. With the unit ON, press and hold the desired
compartment COLDER key and the UNIT ON/OFF key for ten seconds
The evaporator tempera-
ture for that compartment will be displayed in the left display area of the LCD and the right display area will show the
thermistor location.
NOTE:
If the COLDER and UNIT ON/OFF keys are pressed and held for less then 10 seconds, Diagnostic Mode
will be initiated. This was covered earlier in the section.
NOTE:
It is possible to toggle through the the other temperature readings as in Diagnostic Mode, but in this case
the temperature readings will last for five minutes rather than twenty seconds.
NOTE:
The compressor overload could prevent the compressor from energizing.
NOTE:
Manual Component Activation Mode will end five minutes after it is initiated. It is possible to end this five
minute run time and return to normal operation by switching the unit OFF then back ON. If this is done, note that
the electronic control will observe a three minute minimum compressor OFF time when the unit is switched back
ON. This is to protect the compressor and its electricals.
UNIT