PROBLEM
POSSIBLE CAUSE
TEST / ACTION
A.) Warm Freezer Temperature
with “SERVICE” Flashing
Pointers:
Verify freezer comp is running &
unit is not in defrost, then initiate
Diagnostic Mode and observe
freezer evaporator temperature.
1. Evaporator temp -20°F or
lower, see:
• Door ajar
• Lights ON w/door closed
• Evaporator fan fault
• Compartment thermistor mis-
read
• Evaporator heavily frosted
• Sealed system fault - leak or
partial restriction
2. Evaporator. Temp. between
-19°F & 10°F, see:
• Condenser Air Flow
• Compartment thermistor mis-
read
• Sealed system fault, leak
3. Evaporator. Temp. 20°F or
higher, see:
• Power to compressor fault,
• Sealed system fault, leak,
restriction or inefficient com-
pressor
(
NOTE:
“Pointers” do not apply to
cabinet initial pulldown from
ambient temperatures.)
(
NOTE:
To clear SERVICE
annunciator after repairs, power
OFF, then back ON.)
(Continued)
Door or Drawer Ajar
a. Food product obstruction
b. Door/cabinet hinge problem
c. Drawer closer tripped backwards
Condenser Air Flow
a. Dirty condenser
b. Condenser fan blade obstructed or
loose
c. Condenser fan motor disconnected
d. Condenser fan motor defective
e. Power from control board fault
(700TC/I-2 & 700TR-2 only)
f. Power from compressor controller fault
(700TF/I-2V only)
Light ON with Door/ Drawers Closed
a. Top hinge cover missing, not depress-
ing light switch
b. Faulty light switch
Evaporator Fan Fault
a. Top hinge cover missing, not depress-
ing fan switch
b. Fan blade obstructed or out of position
c. Faulty fan switch
(
NOTE:
A compressor must be running)
d. Evaporator. fan motor disconnected
e. Evaporator fan motor defective
(
NOTE:
Compressor must be running)
Compartment Thermistor Misread
a. Move obstruction.
b.
See Door Hinge Operation Test Procedures
later in this section. Replace hinge if defec-
tive.
c. Trip drawer closer forward
a. Clean condenser.
b. Remove obstruction or tighten nut on motor
shaft.
c. Check continuity from motor to control board
(J7-1) on 700TC/I-2 & 700TR-2, from motor
to compressor on 700TF/I-2, or from motor
to compressor controller on 700TF/I-2V .
Reconnect / repair wiring or connections.
d. Check for 115V AC to motor, replace motor
if defective.
e. With compressor running, check for 115V
AC at control board (J7-1 on 700TC/I-2 &
700TR-2). Replace board if defective.
f. With compressor running, check for 115V
AC from controller (700TF/I-2V only).
Replace compressor controller if defective.
a. Replace hinge cover.
b. Check operation of light switches, lights off
when switch is depressed. Replace switch if
defective.
(
NOTE:
there are two light switch-
es in the drawer area)
a. Install hinge cover.
b. Move obstruction or reposition blade.
c. Check for 115V AC to fan switch, depress
fan switch and check for 115V AC from fan
switch. Replace switch if defective.
(
NOTE:
there are two fan switches in the drawer
area)
d. Check electrical connections of motor.
Reconnect / repair bad connections.
e. Check for 115V AC at fan motor with fan
switch depressed. Replace motor if defec-
tive.
Check resistance of freezer compartment
thermistor for 30,000 to 33,000 ohms at
32°F. Replace if defective.