Page 122
Troubleshooting Guides
Integrated (
Integrated (
700-
700-
2) Series
2) Series
8-16
#
3756780
- Revision D - July, 2005
PROBLEM
POSSIBLE CAUSE
TEST / ACTION
E. Warm or Normal
Temperatures in Both
Compartments with
“SERVICE” Flashing
F. Warm or Normal Temp. in
One or Both Compartment
with “SERVICE” Flashing
and “EC” on the LCD
G. Warm or Normal Temp. in
One or Both Compartment
with “SERVICE” Steady, but
not Flashing on the LCD
High Room Ambient
Condenser Air Flow
a. Dirty condenser
b. Condenser fan blade obstructed or
loose
c. Condenser fan motor disconnected
d. Condenser fan motor defective
e. Power from control board fault
(700TC/I-2 & 700TR-2 only)
f. Power from compressor controller fault
(700TF/I-2V only)
Refrigerator Evaporator Thermistor
Disconnected or Shorted
Excessive Compressor Run with Error
Codes Logged
Error Codes were Logged, were
Observed, but were not Cleared
Instruct customer unit performs best
between 60°F(16°C) and 90°F(32°C).
a. Clean condenser.
b. Remove obstruction or tighten nut on motor
shaft.
c. Check continuity from motor to control board
(J7-1) on 700TC/I-2 & 700TR-2, from motor
to compressor on 700TF/I-2, or from motor
to compressor controller on 700TF/I-2V .
Reconnect / repair wiring or connections.
d. Check for 115V AC to motor, replace motor
if defective.
e. With compressor running, check for 115V
AC at control board (J7-1 on 700TC/I-2 &
700TR-2). Replace board if defective.
f. With compressor running, check for 115V
AC from controller (700TF/I-2V only).
Replace compressor controller if defective.
Initiate Diagnostic Mode. If “EE” appears in
place of refrigerator evap temp, check refrig-
erator evaporator thermistor electrical con-
nections from thermistor to J1 on control
board. Reconnect / repair connections.
Check resistance of refrigerator evaporator
thermistor for 30,000 to 33,000 ohms at
32°F. Replace if defective.
See Error Code Table and Error Code
Troubleshooting Guide. Also see “A”, “C”
and “E” in General Troubleshooting Guide.
rected and Error Codes were simply not
cleared, press Bell ON/OFF key for 15 sec-
onds.