Page 14
Electronic Control
Integrated (
Integrated (
700-
700-
2) Series
2) Series
3-4
#
3756780
- Revision D - July, 2005
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
LCD (DISPLAY)
J6
J4
J1
E7 E10 E6
E2
J2
J3
J7
J5
PIN 1
BOARD CONFIGURING
RESISTORS
Figure 3-2. 700-2 Tall Unit Control Board Layout
Figure 3-3. 700-2 Tall Unit Control Board Summary Table (700TC/I-2 Summary Table Shown)
700-2 TALL UNIT CONTROL BOARD LAYOUT AND SUMMARY TABLE
The electrical connection points on the 700-2 tall unit control board are labeled alphanumerically. These labels cor-
respond with the alphanumeric control board summary table, located on all 700 Series wiring diagrams. By refer-
encing the summary table, it is possible to identify which components are connected at which connection points on
the control board. Below is a layout diagram of the control board, and a copy of a summary table.
NOTE:
All components on the control board are non-replaceable. If a problem with the control board is identified,
the complete control board must be replaced.
DEFROST HEATER
ICE MAKER VALVE SENSOR
DEF SENSOR
ICE MAKER ACC (FILL TUBE)
ICE MAKER
POWERS ICE MAKER
SENSES WATER VALVE ACTIVATION
SENSES WHEN DEF HEATER SHUTS OFF
POWERS FILL TUBE HEATER AND ACCESSORIES
POWERS DEFROST CIRCUIT
WHITE/BLUE
GRAY/WHITE
TAN
BLUE
PINK
BLUE/BLACK
BLUE/BLACK
BLUE/YELLOW
ORANGE/YEL
BLUE/WHITE
BLUE/WHITE
BLUE/RED
ORANGE/RED
WHITE/RED
LOW VOLTAGE THERMISTOR CIRCUITS
REF EVAP
FRZ COMPARTMENT
FRZ COMPARTMENT
REF COMPARTMENT
REF COMPARTMENT
REF EVAP
FRZ EVAP
NOT USED(NO PIN)
DOOR LIGHTS SENSE
DRAWER LIGHTS SENSE
NOT USED(NO PIN)
NOT USED
NOT USED
CONDENSER FAN
REF COMPRESSOR
LIGHTS
NEUTRAL
DESCRIPTION
POWER IN
120 VOLT CIRCUITS
FRZ COMPRESSOR
J7-1
C FAN
DEF HTR
E2
E6
E7
E10
CIRCUIT
RCOMP
FCOMP
L1
J7-5
J7-3
J7-2
J7-4
J4-1
J7-7
J7-6
J7-8
E FAN
LITES
NEU
J1-4
J4-5
J4-4
J4-3
J4-2
J1-3
J1-2
J1-1
J1-8
J1-7
J1-6
J1-5
CONTROL BOARD SUMMARY
SENSES FRZ CABINET TEMP (DRAWERS)
SENSES FRZ CABINET TEMP (DRAWERS)
SENSES REF CABINET TEMP
SENSES REF CABINET TEMP
SENSES REF EVAP TEMP
SENSES REF EVAP TEMP
SENSES FRZ EVAP TEMP (DRAWERS)
SENSES IF DOOR OPEN
SENSES IF EITHER DRAWER OPEN
POWERS CONDENSER FAN
POWERS REF COMPRESSOR (DOOR)
POWERS LIGHTS
POWERS FRZ COMPRESSOR (DRAWERS)
POWER INTO BOARD
NEUTRAL INTO BOARD
FUNCTION
COLOR
GRAY
PURPLE
BLACK
YELLOW
ORANGE
WHITE
ORANGE
SENSES FRZ EVAP TEMP (DRAWERS)
FRZ EVAP
IACC
ICE
F DR
R DR
EVAP FRZ
EVAP FRZ
EVAP REF
EVAP REF
REF
REF
FRZ