Page 133
Troubleshooting Guides
Integrated (
Integrated (
700-
700-
2) Series
2) Series
8-27
#
3756780
- Revision D - July, 2005
PROBLEM
POSSIBLE CAUSE
TEST / ACTION
KK.
No Ice in BFI-2, "ICE" is
Displayed on LCD
Unit Has Not Run Long Enough
Warm Freezer Temperatures
(
NOTE
:
Freezer must be 17°F or colder for
icemaker to function)
Shut-off Arm Stuck in Up/Off Position
Disconnected or Defective Water Valve
Icemaker System Fault
a. Disconnected or damaged electrical
connections at icemaker or water valve.
b. Defective icemaker
c. Defective icemaker
d. Disconnected or damaged electrical
connections at icemaker
e. Icemaker switch disconnected or faulty
f. Electrical connection at control board or
control board defect
Frozen Fill Tube
a. Water Supply Problem
b. Disconnected or defective fill tube
heater
Freezer must be 17°F for icemaker to oper-
ate, approximately 24 hours after unit instal-
lation. Instruct customer.
See PROBLEM AA and DD earlier in
Troubleshooting Guide.
Check shut-off arm, if stuck in up/off posi-
tion, correct problem.
Check electrical connections and water con-
nections at water valve, Reconnect / repair
connections.
Check resistance of water valve, 160 ohms.
Replace if defective.
Pressing ICE key to OFF, then to ON to
bypass 45 minute dwell. Then, depress ice-
maker switch & manually start icemaker with
jumper between ports “T” & “H”. Watch
cycle of icemaker and see #1, #2 & #3
below.
1. If icemaker motor starts and finishes cycle:
a. Check for 115V at valve during fill mode. If
no 115V, inspect connections at icemaker
and valve. Repair or replace connection.
b. Check for 115V from icemaker during fill
mode. If no power, replace icemaker.
2. If icemaker motor starts but does not finish
cycle:
c. Replace icemaker.
3. If icemaker motor does NOT start:
d. Check for 115V to icemaker. If no power,
repair electrical connection.
e. Check power to/from icemaker switch.
Repair connection, replace defective switch.
f. Check for 115V at control board (P-10). If
no power, replace control board. If power,
repair connection.
a. Check water supply pressure; must be con-
stant 20-100 PSI. If not, instruct customer.
b. Check electrical connections at fill tube
heater. Reconnect / repair connections.
Check resistance of fill tube heater, 2300 -
2900 Ohms. Replace if defective.