Hydraulic oil
Stryker part number 6500-001-293
Power system
Battery
24 VDC NiCd - S
SM
MR
RT
T power system
Charger
100-240 VAC 1.20 A,
50/60 Hz or 12 VAC 4.16 A - S
SM
MR
RT
T power system
Cot duty cycle
16.7% (less than 60 seconds on, more than 300
seconds off)
Standards (cots and chargers)
ANSI/AAMI ES60601-1:2012, CAN/CSA-C22.2 No.
60601-1:14, KKK-A-1822
For standards that require specific options, see
Standards with required options
1
Cot loads over 300 lb (136 kg) may require additional assistance to meet the set cot load height.
2
Height measured from bottom of mattress at seat section to ground level.
3
Cot is weighed with one battery and without mattress and restraints.
4
Set the cot height to any ambulance deck height that ranges from 26 in. to 36 in. (66 cm to 91 cm).
Stryker reserves the right to change specifications without notice.
P
Po
ow
we
err--P
PR
RO
O XT is designed to conform to the Federal Specification for the Star-of-Life Ambulance (KKK-A-1822).
P
Po
ow
we
err--P
PR
RO
O XT is designed to be compatible with some competitive cot fastener systems.
The yellow and black color scheme is a proprietary trademark of Stryker Corporation.
Hereby, Stryker declares that the radio equipment type short range device is in compliance with Directive 2014/53/EU. The
full text of the EU declaration of conformity is available at the following internet address: http://techweb.med.strykercorp.
com/EMS/EU%20Declaration%20of%20Conformity/index.html.
Labels may be unreadable from a viewing distance greater than 12 inches.
W
WA
AR
RN
NIIN
NG
G -- P
Po
ow
we
err--P
PR
RO
O with the P
Po
ow
we
err--L
LO
OA
AD
D compatibility option operates primarily at these frequencies: 70 - 85 kHz
for inductive charging and 13.56 MHz±7 kHz, Amplitude Modulated (OOK), ERP: -82.37 dBm. The inductive charging can
operate between these frequencies: 70 - 125 kHz. Other equipment may interfere with the P
Po
ow
we
err--L
LO
OA
AD
D system, even if
that other equipment complies with CISPR emission requirements.
E
En
nvviirro
on
nm
me
en
ntta
all cco
on
nd
diittiio
on
nss
O
Op
pe
erra
attiio
on
n
S
Stto
orra
ag
ge
e a
an
nd
d ttrra
an
nssp
po
orrtta
attiio
on
n
Temperature
130 °F
(54 °C)
-30 °F
(-34 °C)
130 °F
(54 °C)
-30 °F
(-34 °C)
Relative humidity
93%
0%
93%
0%
Atmospheric pressure
1060
hPa
700
1060
hPa
700
C
CA
AU
UT
TIIO
ON
N -- This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their expense.
EN
10
6506-109-002 Rev G.1
Summary of Contents for Power-PRO XT
Page 2: ......
Page 6: ......
Page 57: ...6506 109 002 Rev G 1 51 EN ...
Page 58: ...EN 52 6506 109 002 Rev G 1 ...
Page 59: ...6506 109 002 Rev G 1 53 EN ...
Page 103: ...6506 109 002 Rev G 1 97 EN ...
Page 122: ...EN 116 6506 109 002 Rev G 1 ...
Page 185: ......