Option
Setting
SynchroSpeed
This setting synchronizes the speed of the disc and the specimen
holder. If you change the speed of one of these parameters, the
speed of the other parameter will be changed automatically.
You can use this setting within the range of 50 - 300 rpm.
•
Yes
:
Activates synchronized speed change.
•
No
:
Deactivates synchronized speed change.
Cover opening delay
0 - 60 seconds
AUX. Off delay after
process stop
0 - 180s
This function is used when auxiliary equipment is connected via the
AUX panel on the machine.
If an exhaust system is connected via the AUX. connection, it will
continue extracting air for 30 seconds after the process has stopped.
Shift valve installed
•
Yes
:
When a shift valve is installed.
•
No
:
When a shift valve is not installed.
Beacon installed
•
Yes
:
When a beacon is installed.
•
No
:
When a beacon is not installed.
6.4
Preparation methods
The software includes 10 Metalog Guide methods, which you can use to set up your preparation
methods.
These methods have been developed according to the following standard:
300 mm
6 specimens with a diameter of 30 mm clamped in a specimen holder
with a diameter of 160 mm.
350 mm
8 specimens with a diameter of 40 mm clamped in a specimen holder
with a diameter of 200 mm.
You can save these methods under a name of your choice, and adjust them to suit your
requirements.
Creating a preparation method
You can create a preparation method in several ways:
•
Create a preparation method
To create a preparation method, see
Creating a preparation method ►32
•
Change a preparation method and save it under another name
6 Operating the device
AbraPol-30
31