Connecting the unit to the machine
1.
Connect the water inlet hose to the quick
coupling on the recirculation pump.
A
Electrical power socket - not shown
B
Water inlet hose - to machine
C
Recirculation pump
D
Quick coupling - on pump
2.
Insert the water outlet hose from the machine
into the large hole of the filter unit. If needed,
shorten the hose.
3.
Connect the cable from the recirculation
pump to the electrical power socket of the
recirculation unit inside the compartment.
4.
Make sure that the direction of the flow is as
stated with an arrow on the pump. If the
direction is incorrect, switch two of the
phases:
–
EU cable: switch two of the phases.
–
UL cable: switch phases L1 and L2.
5.
Push the unit into place in the compartment
under the machine.
5.11
Connecting an external recirculation unit (option)
1.
Guide the water outlet hose through the opening on the left or
right side of the machine to the recirculation unit.
2.
Connect the water outlet on the pump to the water inlet hose.
ELECTRICAL HAZARD
Make sure that the electrical power supply voltage corresponds to the voltage
stated on the type plate of the pump.
Incorrect voltage can damage the electrical circuit.