Faults, Cause and Remedy
7 — 4
06_0049_0802GB
Pressure has built up while the machine was operating. The compressor has switched off
automatically after reaching the cut-out pressure threshold. The machine does not switch on
again even though the tank pressure has decreased.
Cause
Remedy
The dump valve is
contaminated and does not
blow out.
Clean the dump valve.
Replace the dump valve if necessary.
The compressor does not generate sufficient pressure. The ”working pressure” and ”tank
pressure” gauges display the same pressure.
Cause
Remedy
Air consumption is excessive.
Stop operation.
Wait until the tank pressure has increased again.
The ”tank pressure” gauge displays a higher pressure than the
”working pressure” gauge.
Resume operation.
Stop operation.
Reduce the working pressure.
Resume operation.
Air consumption is excessive.
Maximum output is insufficient.
Use a more powerful compressor.
The compressor blows out compressed air continuously.
Cause
Remedy
The check valve is contami-
nated.
Unscrew the cover on the check valve and clean it.
Continued next page