Maintenance Chart
43--042
Page 2 of 2
8 — 14
WK43_042_0802GB
The following steps describe how to clean and change the air filter:
"
Remove the air filter.
"
Remove the filter cover.
"
Pull the filter insert carefully from the filter housing. Avoid
disturbing dust where possible.
"
Clean the inside of the filter housing and cover with a clean
cloth. Pay particular attention to cleaning the sealing surfaces.
"
Inspect the filter element.
Note
Heavily soiled or damaged filter elements should be replaced with
new elements and discarded.
"
Clean the filter element by blasting dry air from the inside to the
outside.
Note
When blowing out, the air pressure must not exceed 5 bar. The filter
element must not be damaged. A suitable distance must be
maintained between hose nozzle and filter element.
"
Place the cleaned or new filter element in the filter housing.
"
Fit the filter lid again. Ensure that it is correctly seated.
"
Install the air filter again. Ensure that it is correctly seated.
"
Clean or replace the second air filter in the same way.