Stride Industrial Ethernet Switches User Manual 2nd Ed. Rev. A
Chapter 4 - Managed Switch Software Setup
4-68
Trap Managers to Notify:
Use the Trap Managers Menu to specify where traps will be sent. The Trap Managers Menu
can be accessed by selecting Setup from the Main Menu and then selecting Main Settings. Up
to five trap managers may be configured. For each one, the following values may be specified.
• Host:
The IP address of the host where the trap manager is located.
• Community String:
The community string to use when contacting the trap manager on the host.
• Version:
The SNMP trap version to send.
NOTE: There are two system traps that cannot be disabled and will be sent to any configured trap managers. A coldStart
trap will be sent whenever the SNMP agent starts up (usually, this is only when the Switch is reset). A NotifyRestart trap
will be sent whenever the SNMP agent’s configuration changes and is reloaded. This will happen, for example, when
you commit changes on a configuration menu that includes SNMP settings.