Monitoring Settings
Alarm (OK) Output
These settings control the events that will trigger the alarm output. The OK discrete output is
on during normal conditions and turned off in the event of an alarm condition.
Both Power Inputs On:
An alarm condition will be triggered if power is not on for both
power inputs.
Ring Failure:
An alarm condition will be triggered when a ring failure occurs.
Ring failure on a local port will be triggered when one of this switch’s neighbors in the ring
goes down; the general ring failure option will be triggered when any switch in the ring goes
down.
The general ring failure option implies that local ring port failure is also detected.
Ports Linked:
An alarm condition will be triggered whenever any of the selected ports are not
linked.
4-62
Chapter 4 - Managed Switch Software Setup
Stride Industrial Ethernet Switches User Manual 2nd Ed. Rev. A