DHW set point normal/day time:
(parameter P4 AA = 1/2)
D H W s e t p o i n t
6 0 ° C
This is the water temperature set point that is active during
the programmed DHW periods (parameter P4 AA = 1/2).
DHW set point reduction:
(parameter P4 AA = 1/2)
D H W R e d u c e
1 0 ° C
The reduction of the DHW set point related to normal/day
time set point. This reduction is used outside the pro-
grammed DHW periods (parameter P4 AA = 1/2).
10.10.
Setting the timer programs
Three different programs can be set with the boiler, these are:
•
CH program
•
DHW program
•
Anti-Legionnaires’ disease (pasteurisation) program