
Operating & Maintaining the Objet1000 - Connex 2 3D Printer
6–38
DOC-06800 Rev. A
4. When the following screen appears, open the printer and place the UV
sensor at the rear edge of the tray, in the center.
Figure 6-48: Place the sensor screen
Figure 6-49: Correct UV-sensor placement
5. Make sure that the sensor cable is securely connected to the sensor.
6. Lead the cable out of the printer so that you can close the printer, and
make sure that the cable will not interfere with the moving print block.
7. Close the printer, while checking that the sensor does not move out of
position.
8. Set the UV meter to measure mJ/cm2.
9. Set the range on the meter to 2,000.
10. Connect the cable from the sensor to the UV meter.
11. Turn on the UV meter, and wait until 0 0 0.0 appears on the display.
D R A F T
16 June 2013
Summary of Contents for Objet1000 Connex 2
Page 1: ...User Guide English Objet1000 Connex 2 3D Printer System D R A F T 16 June 2013...
Page 2: ...D R A F T 16 June 2013...
Page 8: ...Objet1000 Connex 2 User Guide viii D R A F T 16 June 2013...
Page 20: ...Safety 2 8 DOC 06800 Rev A D R A F T 16 June 2013...
Page 30: ...Introducing the Objet 3D Printing System 3 10 DOC 06800 Rev A D R A F T 16 June 2013...
Page 36: ...Installing Objet Software 4 6 DOC 06800 Rev A D R A F T 16 June 2013...
Page 120: ...Using Objet Studio 5 84 DOC 06800 Rev A D R A F T 16 June 2013...