Page 53 /59
snengde_installation-product-SN-range v1.2 - Copyright Netasq 2015
PRESENTATION AND INSTALLATION GUIDE – SN RANGE
APPENDIX F: MANAGING SSDs
-
SN3000 and SN6000 (SSD in RAID1):
This procedure is to be carried out on an appliance that is running. After having extracted the defective SSD,
insert the new SSD, which you would have obtained from your partner, then type the following command to
scan the newly inserted SSD:
nraid –z.
Next, type the command to rebuild the RAID:
nraid -r
Big Data Option
If you have subscribed the
Big Data
option(available on SN3000 and SN6000 models), the original SSDs will
be replaced with SSDs of greater capacity. After you have shut down the appliance, you will be able to extract
the SSDs. Next, insert the new SSDs, which will be detected the next time you start the appliance.