Page 42 /59
snengde_installation-product-SN-range v1.2 - Copyright Netasq 2015
PRESENTATION AND INSTALLATION GUIDE – SN RANGE
INITIAL CONNECTION TO THE PRODUCT
Shutting down
SN150
Log on to the configuration interface. Go to the Maintenance module (System menu) and click on “Shut down
the Firewall”.
Then wait for several minutes until the
Online
and
Status
LEDS go out. For this model, upon shutdown, the
LEDs shut off in the following order:
Online
1
Status
2
The
Power
LED will stay lit if the product is powered up.
SN200, SN300, SN500, SN700, and SN900
To shut down your Firewall, press once on the ON button then wait for several minutes for the 3 LEDs
Online
,
Status
and
Power
to go off.
For all models, upon shutdown, the LEDs shut off in the following order:
Online
1
Status
2
Power
3
A beep will indicate that the appliance is in the process of shutting down.
SN910
Log on to the configuration interface. Go to the Maintenance module (System menu) and click on “Shut down
the Firewall”. Then wait for several minutes until the Power LED goes out.
SN2000, SN3000 and SN6000
To shut down your Firewall, press once on the ON button. For SN2000 and SN3000 models, the procedure is
the same as the one described in the paragraph relating to SN200, SN300, SN500, SN700, and SN900,
without the
Status
LED.
For SN6000 model, the only indication that the product has shut down is an extinguished
Power
LED.
General remarks
-
The
Status
2
LED will blink in the event of a major product failure (hardware component failure,
faulty network interface, etc.). Contact your reseller in this case.
-
During startup, shutdown or upgrading, only the LEDs
Status
2
and
Power
3
will light up.
-
In High Availability mode, when the Firewall is in passive mode, the
Online
1
LED will blink (about
2 seconds off for every 1 second it is on).
-
During the reset phase (
defaultconfig
), the O
nline
and
Status
LEDs will blink.
-
To reboot an SN150 appliance that is still powered up (only the
Power
LED is lit), you will need to
unplug and plug the Firewall back into the mains socket. It is also possible to reboot in console