206 VM/HSC 6.0 System Programmer’s Guide
1st ed., 6/30/04 - 312579601
Note:
If a CAP is not specified, a CAP in the identified ACS is selected based
on the CAPPref operator command (refer to the ‘‘CAP Preference (CAPPref)
Command and Control Statement’’ in the
HSC Operator’s Guide
).
Multi-ACS audits cannot specify the CAP parameter. A CAP is chosen for each ACS
based upon CAP preference values.
EMPTYCel
optionally specifies that only empty cells are to be audited.
This parameter can be
used in combination with all other AUDIt parameters except
DIAGScan(ONLY)
.
The main benefit provided by auditing only empty cells is reducing the time required
to run an audit.
Note:
StorageTek does not recommend running an empty cell audit on an SL8500
library because the time to run the audit will not be substantially reduced.
Typically, users will want to specify this parameter when:
• they have entered an LSM and placed new cartridges in empty cells, or
• they need to correct cartridge location information for library volumes that have
been manually moved to empty cells.
In either case, if APPLy(YES) is specified, the CDS is updated to reflect that these
cells are no longer empty.
Caution:
In some cases, running an empty cell only audit may compromise the
accuracy of the audit.
DIAGScan
optionally specifies that diagnostic cells are to be scanned. The HSC scans these cells
one at a time and displays the contents of each cell in the AUDIt utility report.
Notes:
1.
DIAGScan is mutually exclusive with the ROW and COLumn parameters.
It can be used in combination with all other AUDIt parameters.
2. Cartridge movement between diagnostic cells and regular storage or CAP cells
is not supported by the LMU, so diagnostic cell contents can only be reported.
ONLY
specifies that only diagnostic cells should be scanned.
This parameter cannot
be specified in combination with the EMPTYCel parameter.
ALSO
specifies that diagnostic cells should also be scanned along with the normal
AUDIt utility operations.
Audit
Summary of Contents for Host Software Component 6.0
Page 1: ...Host Software Component VM Implementation System Programmer s Guide Release 6 0 312579601...
Page 4: ...iv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 24: ...xxiv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 30: ...xxx VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 48: ...18 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 198: ...168 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 376: ...346 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 627: ...Appendix C Record Formats 597 1st ed 6 30 04 312579601 UVD994B5 CVAL Name Len Offset Value...
Page 632: ...602 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 683: ...Appendix F Batch Application Program Interface API 653 1st ed 6 30 04 312579601...
Page 684: ...654 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 700: ...1st ed 6 30 04 312579601 670 VM HSC 6 0 System Programmer s Guide...
Page 716: ...686 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 717: ......
Page 718: ...Printed in U S A...