Chapter 4. Utility Functions 199
1st ed., 6/30/04 - 312579601
You can specify whether or not the library control data set is updated as a result of audit, or
if only the discrepancy listing is produced by the parameters chosen.
• If the APPly(YES) is specified, the library control data set is updated to reflect all
observed contents in cell storage. A discrepancy listing is also produced. Duplicate
VOLSERs and cartridges with unreadable or illegal external labels are ejected from
the LSM. Cartridges that are not recorded in the CDS that have external media labels
that are unreadable are also ejected.
Note:
The discrepancy list identifies differences between the CDS and the physical
inventory. APPly(YES) is the default setting.
• If APPly(NO) is specified, duplicate VOLSERs and cartridges with
unreadable/illegal external labels are not ejected, the library control data set is not
updated, and a discrepancy listing is produced.
Media Type Mismatch Conditions
The Audit utility can address a mismatch condition if the LMU reports a different media
type than the CDS contains. In this case, an unreadable external media label exists, and the
vision system cannot determine the media type.
Note:
CDS media information is updated when the volume external label is read by the
robotic vision system and is transmitted back to the HSC through the LMU.
It is recommended that users provide an external media label for all cartridges.
An
SL8500 library will not enter a non-labeled cartridge.
Depending on the parameters input by the user, the following actions occur:
1. If APPLY(YES) is specified (or defaulted to):
• If the LMU and a VOLATTR are mismatched, the VOLATTR is incorrect, and
the HSC issues a warning message.
• If the media values for the LMU and the VAR do not agree, the HSC issues a
warning message, and the CDS is updated to reflect the value reported by the
LMU.
• If the media value is unreadable by the LMU (for a cartridge recorded in the
CDS), the HSC issues a warning message, and the CDS is updated to indicate
that the media value of this volume is unreadable.
• If the media value is unreadable by the LMU (for a cartridge not recorded in the
CDS), the HSC issues a warning message, and the volume is ejected.
2. If APPLY(NO) is specified:
• If the LMU and a VOLATTR are mismatched, the VOLATTR is incorrect, and
the HSC issues a warning message.
• If the media values for the LMU and the VAR do not agree, the HSC issues a
warning message.
Audit
Summary of Contents for Host Software Component 6.0
Page 1: ...Host Software Component VM Implementation System Programmer s Guide Release 6 0 312579601...
Page 4: ...iv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 24: ...xxiv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 30: ...xxx VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 48: ...18 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 198: ...168 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 376: ...346 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 627: ...Appendix C Record Formats 597 1st ed 6 30 04 312579601 UVD994B5 CVAL Name Len Offset Value...
Page 632: ...602 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 683: ...Appendix F Batch Application Program Interface API 653 1st ed 6 30 04 312579601...
Page 684: ...654 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 700: ...1st ed 6 30 04 312579601 670 VM HSC 6 0 System Programmer s Guide...
Page 716: ...686 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Page 717: ......
Page 718: ...Printed in U S A...