5
Maintenance
General maintenance information
At operating hours
1000
2000
4000
5000
7000
Carried out
8000
10000
11000
13000
14000
Check the solenoid shut-off valve, and if necessary check the high-pressure relief
valve (1.7 bar)
Check the gas cylinder valve for cleanliness and correct function, check the over-
pressure safety device (30 bar)
Change the LPG filter
Change the evaporator (C Series) or overhaul the evaporator (MD/Cobra) Replace
the sticker
Check the screw joints for secure attachment and perform a leak test
Check the CO content in the exhaust gas
Check that the duration of engine run-on before the engine stops is acceptable
Steering
Check the steering system for correct function and for leaks
Check that the steering wheel is securely attached and check the turning handle for
damage
Steering axle: Check that the steering axle is securely attached, check for leaks and
apply grease
Check the steering stop
Brake
Check the condition of all mechanical brake parts and check for correct function
Perform brake test
Electrical system
Check all power cable connections
Check the switches, transmitters and sensors for correct function
Check the lighting and indicator lights
Starter battery
Measure the cold-start current; recharge or replace the battery if necessary.
Hydraulics
Check the condition of the hydraulic system, and check for correct function and leaks
Check the oil level
Lift mast
Check the mast bearings for damage and lubricate the mast bearings, and check the
tightening torque
Check the mast profiles for damage and wear, and lubricate the mast profiles
308
174749 EN - 03/2017
Summary of Contents for RX70-16
Page 1: ...Original instructions Diesel truck RX70 16 RX70 18 RX70 20 7311 7312 7313 174749 EN 03 2017 ...
Page 2: ......
Page 4: ......
Page 13: ...1 Foreword ...
Page 35: ...2 Safety ...
Page 49: ...Safety 2 Residual risk 174749 EN 03 2017 37 ...
Page 67: ...3 Overviews ...
Page 78: ...3 Overviews Operating and display elements 66 174749 EN 03 2017 ...
Page 79: ...4 Operation ...
Page 310: ...4 Operation Shutdown 298 174749 EN 03 2017 ...
Page 311: ...5 Maintenance ...
Page 318: ...5 Maintenance General maintenance information 306 174749 EN 03 2017 ...
Page 322: ...5 Maintenance General maintenance information 310 174749 EN 03 2017 ...
Page 354: ...5 Maintenance Remaining ready for operation 342 174749 EN 03 2017 ...
Page 359: ...6 Technical data ...
Page 367: ...Technical data 6 Ergonomic dimensions 174749 EN 03 2017 355 ...
Page 378: ......
Page 379: ......
Page 380: ...STILL GmbH 174749 EN 03 2017 ...