PROGRAMMING MODE — to be carried out with the truck switched off (2)
Restoring the ini-
tial administrator
code
To reactivate the default
administrator code
(00000000), please con-
tact your agent or near-
est dealer.
Activating the au-
tomatic switch-off
*
*
2
*
1
#
● red flashing ● green
flashing (5) (5 s before
switch-off)
The power supply
switches off automatical-
ly after 10 min. (600 s by
default) if the truck is not
being used.
Setting the delay
of the automatic
switch-off
*
*
3
*
6
0
#
○ red off ● green flash-
ing (2) (value accepted)
Example: automatically
switches off after 1 min.
(60 s) if not used.
Minimum setting = 10 s /
maximum = 3000 s
Deactivating the
automatic switch-
off
*
*
2
*
0
#
○ red off ● green flash-
ing (2) (command ac-
cepted)
Stand-by
NOTE
The stand-by function is only available with
the Digicode option.
To prolong battery life, the truck can be put in-
to energy-saving mode when it is not in use.
After a certain period of downtime, the truck
switches off.
This time period can be configured between 0
and 10 minutes. This function is disabled by
default.
Timeout can be adjusted. Contact the Techni-
cal Service Department authorised by the
manufacturer.
Overview
3
Options and variants
75
45758043484 EN - 11/2021 - 08
Summary of Contents for 0301
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 23: ...2 Safety ...
Page 36: ...Safety 2 Safety devices 26 45758043484 EN 11 2021 08 ...
Page 37: ...3 Overview ...
Page 91: ...4 Use ...
Page 131: ...5 Maintenance ...
Page 148: ...Maintenance 5 Decommissioning 138 45758043484 EN 11 2021 08 ...
Page 149: ...6 Technical data ...
Page 166: ...EXP overall dimensions Technical data 6 EXP overall dimensions 156 45758043484 EN 11 2021 08 ...
Page 191: ......