16. Maintenance
WARNING Electrocution
f
f
Before working on the appliance, isolate it from the
power supply at the control panel.
Following isolation from the mains supply, parts of the
appliance may remain live for up to 2 minutes since the
capacitors still have to discharge into the inverter.
DANGER Risk of electrocution!
Prior to maintenance work, isolate the internal and
external units from the power supply.
Note
Ensure that the refrigerant circuit is tested once a year for
leaks, in accordance with EC DIRECTIVE 517/2014.
The tightness test must be documented in the log.
f
f
Before any work on the appliance, disconnect all poles of any
in-built electric components from the power supply.
f
f
Regularly vent the safety valve until a full stream of water
flows from it. Close the safety valve following inspection.
Please note that the heating system is only free of dirt if the strai-
ners are completely clean following a prolonged pump runtime.
!
Material damage
Escaping refrigerant is damaging to the environment.
Any leaks in the refrigerant circuit must be remedied
immediately. Work on the refrigerant circuit must only
be carried out by qualified contractors.
We recommend a regular inspection (to establish the current con-
dition of the system), and maintenance if required (to return the
system to its original condition).
16.1 DHW cylinders
Opening the appliance
26
�0
3�
01
�1
75
4
f
f
Undo the screws and open the appliance door.
26
�0
3�
01
�1
753
f
f
Undo the screws and remove them.
f
f
Remove the lower appliance door.
Draining the DHW cylinder
WARNING Burns
Hot water may escape when draining the DHW cylinder.
f
f
Close the shut-off valve in the cold water line.
f
f
Open the hot water taps on all draw-off points.
1
26
�0
3�
01
�1
75
8
1 Drain
f
f
Empty the DHW cylinder via the drain.
Please note that some residual water will remain in the bottom
of the cylinder.
Cleaning and descaling
f
f
Remove the flange plate.
f
f
Clean the DHW cylinder through the inspection port.
f
f
Never use descaling pumps. Never use descaling agents for
the purpose of cleaning the enamel coating and protective
anode.