INSTaLLaTION
appliance installation
www.stiebel-eltron.com
WPL 15 IKS | WPL 25 IK |
25
10. Appliance installation
10.1 Internal unit
10.1.1 Transport
WARNING Burns
The appliance is filled with refrigerant. Escaping refri-
gerant can cause burns.
f
f
Ensure that the appliance is not damaged.
!
Material damage
The appliance is unsuitable for lifting by hoist.
!
Material damage
The appliance should only be stored and transported at
temperatures of +5 °C to +50 °C.
Angled panels are fitted to the back of the appliance. These can
be used as transport aids.
f
f
Transport the appliance upright and in its packaging to pro-
tect it against damage. Where space is restricted, you may
also briefly move the equipment tipped backwards at an
angle not exceeding 45°.
10.1.2 Siting
D
00000
52
69
8
1
1 Transport aids
D
00000
51
81
3
1
2
1 Appliance foot
2 Sliding block
f
f
Undo the four screws on the underside of the non-returnable
pallet.
f
f
Remove the washers.
f
f
Remove the appliance feet from the pack. Screw the feet onto
the appliance fully, without removing the appliance from the
pallet.
f
f
Take the appliance off the pallet and set it down carefully.
f
f
Observe minimum distances (see chapter „Specification / In-
stallation dimensions“).
f
f
If required, use the sliding blocks provided to help you posi-
tion the appliance.
f
f
Remove the transport aids.
f
f
Level the appliance horizontally by adjusting the feet.
10.2 External unit
10.2.1 Transport
!
Material damage
Protect the appliance from being scraped when fixing
the transport belts.
- Lifting straps to transport the appliance can be hooked into
the area highlighted in grey at the bottom of the support
frame.
26
�0
3�
01
�1
826
!
Material damage
Protect the appliance against impact during transport.